**Common Faults of Lithium Battery Pack Protection Boards**
Lithium battery protection boards (BMS) are critical for ensuring safe and efficient operation, but they can experience several faults. Below are the most common issues, supported by insights from industry sources:
### **1. Overvoltage/Undervoltage Protection Failure**
- **Cause**: Faulty voltage sensing circuits or calibration errors in the BMS can prevent accurate detection of cell voltages.
- **Impact**: Overcharging (leading to thermal runaway) or overdischarging (causing irreversible cell damage) .
- **Detection**: The protection board should trigger balancing or cutoff when cells exceed safe voltage thresholds (e.g., 4.18V for Li-ion, 3.6V for LiFePO4) .
### **2. Short-Circuit Detection Failure**
- **Cause**: Damaged MOSFETs or delayed response in the protection circuitry.
- **Impact**: Uncontrolled current flow, risking fire or explosion if not isolated promptly.
- **Mitigation**: High-quality BMS designs include redundant short-circuit protection layers .
### **3. Balancing Circuit Malfunction**
- **Cause**: Defective balancing resistors, poor solder joints, or software errors.
- **Impact**: Voltage imbalances between cells, reducing pack capacity and lifespan. For example, if one cell charges faster than others, the BMS should activate energy dissipation (resistors) or energy redistribution (capacitive balancing) .
- **Types of Balancing Issues**:
- **Static imbalance**: Failure to equalize cells during idle states.
- **Dynamic imbalance**: Inadequate correction during charging/discharging .
### **4. Overtemperature Protection Failure**
- **Cause**: Faulty temperature sensors or poor thermal design.
- **Impact**: Cells operating beyond safe limits (e.g., >60°C) may degrade rapidly or combust.
- **Solution**: BMS should include redundant thermal sensors and enforce shutdown protocols .
### **5. Component Degradation**
- **Cause**: Aging MOSFETs, capacitors, or PCB traces due to heat, vibration, or moisture.
- **Impact**: Increased resistance, reduced efficiency, or complete circuit failure.
- **Prevention**: Regular testing of components like MOSFETs for switching performance and insulation resistance .
### **6. Parasitic Load (Self-Discharge)**
- **Cause**: High self-consumption by the BMS circuitry or defective cells.
- **Impact**: Gradual battery drain during storage, even when disconnected.
- **Diagnosis**: Measure the protection board’s standby current; excessive values indicate faulty components .
### **7. Communication Errors**
- **Cause**: Broken data lines (e.g., CAN bus, SMBus) or firmware bugs.
- **Impact**: Incorrect state-of-charge (SOC) reporting or failure to relay fault alerts.
### **8. Incorrect Assembly or Design**
- **Cause**: Poor soldering, reversed polarity, or mismatched cell specifications.
- **Impact**: Immediate failure during operation (e.g., arcing, overheating).
- **Prevention**: Follow strict manufacturing standards, such as SJ/T 11852-2022’s requirements for uniform cell selection and mechanical robustness .
### **9. Environmental Stress Damage**
- **Cause**: Exposure to humidity, dust, or extreme temperatures beyond the BMS’s rated IP or thermal thresholds.
- **Impact**: Corrosion, insulation breakdown, or sensor drift .
---
**Key Takeaways**
- Regular testing (e.g., capacity checks, insulation resistance tests) is critical to identify latent faults .
- Prioritize BMS designs with redundancy in critical functions like voltage sensing and thermal management.
- Always source protection boards from certified manufacturers (e.g., Shenzhen Gary Intelligent Technology) specializing in robot or high-vibration applications .
For detailed troubleshooting, refer to the specific BMS technical manuals or industry standards like IEC 62133. ⚠️